. Florists' review [microform]. Floriculture. Far COAL write to HITOELL & DILLON COAL CO. BedfonI Building, CHICAGO _ W* can •«¥• you nonay. Mentton The R«tI«w wh«B yon write. H. H. LINEAWEAVER & CO. Jnc ANTHRACITE and BITUMINOUS West End Trust Building. PHILADELPHIA 17 Battery Place, NEW TORE NattinK BuildinK, LEBANON, PA, Mention The Review when yon write. COAL Greenhouse Heating. HOUSE MAY BE EXTENDED. I have a greenhouse 12x13 and nine feet high to the ridge, and I wish to heat it with hot water. The house runs north and south. The side walls contain twenty-seven inches of glass an


. Florists' review [microform]. Floriculture. Far COAL write to HITOELL & DILLON COAL CO. BedfonI Building, CHICAGO _ W* can •«¥• you nonay. Mentton The R«tI«w wh«B yon write. H. H. LINEAWEAVER & CO. Jnc ANTHRACITE and BITUMINOUS West End Trust Building. PHILADELPHIA 17 Battery Place, NEW TORE NattinK BuildinK, LEBANON, PA, Mention The Review when yon write. COAL Greenhouse Heating. HOUSE MAY BE EXTENDED. I have a greenhouse 12x13 and nine feet high to the ridge, and I wish to heat it with hot water. The house runs north and south. The side walls contain twenty-seven inches of glass and the south end is glass. At the north end there is a building 14x14, in which I shall put the boiler, and this building is protected on the north by a stable. The boiler is a Little QeJh. It has 2-inch and 2%-inch open- ings and a 14-inch firebox, and is rated at 230 square feet of radiation. I should like to know how to pipe this house for a temperature of 60 degrees in zero weather. What size of pipe would be the best to usef If I should add thirteen feet to the south end of the house, would the boiler be large enough to heat itt Should I use the same size of pipe in the enlarged house? W. T. J.—Me. To heat the house described, we would start with a 2Vi-inch flow pipe at the boiler and carry it to a point in line with and about eighteen inches below the ridge. At the point where it turns to enter the house, connect a 5-gallon expansion tank, using a %-inch pipe. Continue the flow pipe through the house, giving it a fall of about two inches, and at the farther end connect with the return coils on the side walls by means of 2-inch pipes. In each of the side coils there should be five 1%- inch returns. These, of course, should also be given a slight fall and should be connected to the return outlet in the boiler. While a 2-inch return con- nection will answer for the present radiation, if the size of the house is to be doubled it will be well, if possi- ble, to ream


Size: 3111px × 803px
Photo credit: © Library Book Collection / Alamy / Afripics
License: Licensed
Model Released: No

Keywords: ., bookcentury1900, bookdecad, booksubjectfloriculture, bookyear1912