Catalog 13: Carrier air washers and humidifiers: applied to public office and industrial buildings, with notes on humidity . soot and bacteria, properly humidified andcooled. The air then passes to the fan and tempering or heatingcoils to be heated sufficiently to maintain the required tem-perature in the building. The spray water, which is recirculated, falls from theeliminator plates to the settling tank, passes through the suc-tion screen, thence to the ejector (where it is heated in winter),then to the pump, and through the basket screen back to thesprays. Types of Machines * While all of


Catalog 13: Carrier air washers and humidifiers: applied to public office and industrial buildings, with notes on humidity . soot and bacteria, properly humidified andcooled. The air then passes to the fan and tempering or heatingcoils to be heated sufficiently to maintain the required tem-perature in the building. The spray water, which is recirculated, falls from theeliminator plates to the settling tank, passes through the suc-tion screen, thence to the ejector (where it is heated in winter),then to the pump, and through the basket screen back to thesprays. Types of Machines * While all of our air washers em-body the same general principles, we have found it necessaryto develop and standardize machines varying in detail for thevarious classes of service to be performed. The machines described in the following pages are eachespecially adapted to certain classes of work, and for thatparticular condition they have no equal. The machines designed for textile mills, turbo-generatorcooling or dehumidifying are described in other publicationswhich will be sent upon request. Details Common to All Carrier Washers. Inspection Door Easy to operate, allows ample opening and remains water tight when closed 10 Carrier Air Conditioning Company of America Details Common to AllCarrier Washers The following details are common to all types of CarrierWashers: The Casing is made in sections rigidly supported by anangle iron frame. The sides, top and tank are made separately,and are bolted together with rubber gaskets, joints thus provid-ing for convenience in assembling and erecting, or for inspectionand repairs. Additional bracing with angle iron is providedso no sheet wider than three feet is unsupported. Each casingis provided with inspection door described below. The angleframe is outside of the sheets, so no water comes in contactwith angles. All seams, or exposed edges of the sheets, andrivet heads are soldered. Inspection Door used in all Carrier Air Washers is areal rigid ser


Size: 1149px × 2174px
Photo credit: © The Reading Room / Alamy / Afripics
License: Licensed
Model Released: No

Keywords: ., bookcentury1900, bookdecade1910, bookidcatalog13car, bookyear1913