. Florists' review [microform]. Floriculture. 128 1 be Rorists Revieu Of rOBKK «. IW.'l Greenhouse Heating Subscribers are invited to write the editor of this department with regard to any details of greenhouse heating that are not understood. When information is desired regarding the capacity of boil- ers, or the amount of radiation required for a greenhouse, the needed temperatures should be stated in the inquiry, as well as the amount of glass in the side walls, and the dimensions and general arrange- ment of the greenhouses. It is often helpful, also, to have a sketch showing the location


. Florists' review [microform]. Floriculture. 128 1 be Rorists Revieu Of rOBKK «. IW.'l Greenhouse Heating Subscribers are invited to write the editor of this department with regard to any details of greenhouse heating that are not understood. When information is desired regarding the capacity of boil- ers, or the amount of radiation required for a greenhouse, the needed temperatures should be stated in the inquiry, as well as the amount of glass in the side walls, and the dimensions and general arrange- ment of the greenhouses. It is often helpful, also, to have a sketch showing the location of tl\e houses. BADIATION INADEQUATE. T have a greenhouse 21x68 feet; the sides aro yix foot hi^h with thirty-six inches of open glass, and tlie height at j^ablc is eleven and one-halt' feet. The west end of the house is glass and ex- posed. The east end is adjacent to the boiler room. I have a boiler with a .30x48-inch grate and o)ie •2\i,-im'h flow and nine IMi-inch return pipes. What are the heating requirements for the house mentioned at .') degrees below zerof H. H. W.—lud. A boiler with a pirate 30x48 inches should be capable of heating Two houses ? of the dimensions described. According to description, the house has three feet of tilass in the two side and one end wall. To heat such a house to 57 degrees when it is .> below zero, .-ibout 700 square feet of hot water radiation Avill be recpiired. This is al- togetlicr too mucli to be supplied by one l!i/a-inch flow pipe. ^Vhile fairly good results would be secured with two liVy- .inch flow pipes, it would be advisable to use three. In addition to the flow l)ipi's, use fifteen ly^-inch, or preferably twelve •_'-inch, ret'urns. To supply 700 square feet of hot water radiation, a 4-incli main flow pipe with a return main of the same size could be used. If the mains are only a few feet in length, it would be possible to use Ibinch ]iipes. Place one flow pipe on each of the side wall plates and the other four feet be


Size: 2429px × 1029px
Photo credit: © Library Book Collection / Alamy / Afripics
License: Licensed
Model Released: No

Keywords: ., bookcontributorunive, bookleafnumber152, booksubjectfloriculture