[Electric engineering.] . se part of the current may flow through the equalizer,and the ammeter would not indicate the full output of themachine. All the current delivered by the machine thuspasses through the circuit-breaker and ammeter ammeter a is connected to its shunt s by means of thesmall cables furnished with the instrument. The lowerterminals of the voltmeter receptacles c, c are connected tothe + and — sides of the machines, as shown. It should benoted that these connections are made to the lower terminalsof the main switch, so that voltmeter readings may beobtained before


[Electric engineering.] . se part of the current may flow through the equalizer,and the ammeter would not indicate the full output of themachine. All the current delivered by the machine thuspasses through the circuit-breaker and ammeter ammeter a is connected to its shunt s by means of thesmall cables furnished with the instrument. The lowerterminals of the voltmeter receptacles c, c are connected tothe + and — sides of the machines, as shown. It should benoted that these connections are made to the lower terminalsof the main switch, so that voltmeter readings may beobtained before the switches are thrown in. The pilotlamps h, h are also connected to the same lines, so that theywill indicate when the machine is up to voltage. The upperterminals of the voltmeter receptacle are connected to thevoltmeter V, so that by inserting the plug, the voltmetermay be connected to either dynamo. The -f- and — bus-bars run across the back of the board to the feeder panels. /. III.—22 54 ELECTRIC LIGHTING. 17. Shunt. Shunt Oc/numo A/°/. Ot/nanfo A/9 2. Fig. 57. § 17 ELECTRIC LIGHTING. 55 Between the generator and feeder panels, the shunt S forthe main ammeter M is inserted, so that the total currentsupplied by the two machines must pass through the shunt,and the ammeter M thus indicates the total current method of connecting the bus-bars to the feedersdepends to some extent on whether the feeders are to passout at the top of the board or whether they are to be carrieddown through the floor. In this case, they are shown con-nected to the bottom terminals of the switches and carrieddownwards. One side of each feeder switch is connecteddirectly to the — bus-bar; the other side connects to the-(-bus-bar through the circuit-breaker g. Lamps k and / maybe connected directly across the bus-bars, or, if desired, theymay be made to indicate when a circuit-breaker is out byconnecting to the outgoing terminals of the feeder k is shown connected in t


Size: 1331px × 1877px
Photo credit: © The Reading Room / Alamy / Afripics
License: Licensed
Model Released: No

Keywords: ., bookcentury1900, bookdecade1900, bookidelectricengi, bookyear1902