. Florists' review [microform]. Floriculture. 88 The Florists' Review January 23, 1919. of the piping will depend upon the loca- tion of the boiler and the benches. If the boiler is at the end of the house where the door is located, we would run a 2i/^-inch flow pipe on the wall next to the adjoining house. At the farther end, after taking off a 2-inch return to be carried back on the same wall underneath the flow pipe, we would carry a 2-inch main across the end of the house and then connect it with a coil of two 2-inch returns to be carried on the exposed wall of the house to the end near th
. Florists' review [microform]. Floriculture. 88 The Florists' Review January 23, 1919. of the piping will depend upon the loca- tion of the boiler and the benches. If the boiler is at the end of the house where the door is located, we would run a 2i/^-inch flow pipe on the wall next to the adjoining house. At the farther end, after taking off a 2-inch return to be carried back on the same wall underneath the flow pipe, we would carry a 2-inch main across the end of the house and then connect it with a coil of two 2-inch returns to be carried on the exposed wall of the house to the end near the heater, where they should be united with the other return and con- nected with the main return. In case the glass door is in the oppo- site end of the house from the boiler, so that it is not possible to carry the sup- ply pipe across the farther end of the house as suggested above, we would run a 2-inch flow pipe upon each side wall, and at the farther end of the house con- nect each flow with a 2-inch return pipe to be caried back under its own flow pij^e. If the location of the benches is such as to permit, we would carry the flow pipes about one foot under the plates or gutters and run tlie returns a foot or two lower. Give both flows and returns a drop of one inch in twenty feet. NEWPORT, R. I. ^ % BOILER FLUES We make a specialty of handlinc carefully selected Boiler Flues, 4-iii. diameter and other sizes, for green- house Posts, etc. Also, we make a specialty of flues for retnbins: boilers. All flues are thoroughly cleaned inside and out, trimmed, and are ready for use. General Sales Agents for Stuttle's Patent Clamp and Elbow for joining flues—no packing, no leaks. New standard pipe and all kinds of green- house fittings. Right prices and prompt shipment. H. MUNSON Est. 1898 Phone Superior 572 1483 Wells St., Chicago % <c Mention Th« R»t1«w whe» yon writ*. PIPE Wrought Iron of sound second-hand Quality with new threads and coupling. 16-ft. lengt
Size: 1481px × 1687px
Photo credit: © Library Book Collection / Alamy / Afripics
License: Licensed
Model Released: No
Keywords: ., bookcentury1900, bookdecad, booksubjectfloriculture, bookyear1912