. Practical electro-therapeutics and X-ray therapy : with chapters on phototherapy, X-ray in eye surgery, X-ray in dentistry, and medico-legal aspect of the X-ray . lectrolytic interrupter forskiagraphic work, and an antiacid interrupter and step-up trans-former for treatment work. This combination makes a very com-plete equipment for the physician who is, by circumstances,compelled to use the alternating current. This equipment is pro- X-RAY APPARATUS 95 vided also with a high-frequency resonator of the Ouclin type,placed above the coil, which greatly condenses the equipment,saving both space


. Practical electro-therapeutics and X-ray therapy : with chapters on phototherapy, X-ray in eye surgery, X-ray in dentistry, and medico-legal aspect of the X-ray . lectrolytic interrupter forskiagraphic work, and an antiacid interrupter and step-up trans-former for treatment work. This combination makes a very com-plete equipment for the physician who is, by circumstances,compelled to use the alternating current. This equipment is pro- X-RAY APPARATUS 95 vided also with a high-frequency resonator of the Ouclin type,placed above the coil, which greatly condenses the equipment,saving both space and time in operating. The three-bulb ventriltube, shown in this illustration, is a valuable addition to the equip-ment, as it chokes back the inverse current, prevents false rays inthe tube, and greatly lengthens the life of the tube. The large number of x-ray coils on the market is very confusingto the inexperienced buyer. Every maker claims that his is thebest, and by the time the buyer has examined the various stylesof coils he is so thoroughly confused that he is ready to give up indespair. Most of the coils do fairly good work, but some are far better. Fig. 58.—Portable x-ray coils. than others. The test of a good coil is the work it does, and no oneshould buy a coil until he is capable of judging that work. Acoil and tube that will make a good, clear picture through thehead or pelvis of an adult in from five to ten seconds will meetall the requirements of an x-ray coil. A coil with a 16-inch sparkgap will be as large as needed for the most exacting work. Quite an interest was taken for a time in portable x-ray coils are in reality only high-frequency transformers. is an example of this class of coils, and they are of particular 96 PRACTICAL ELECTRO-THERAPEUTICS AND X-RAY THERAPY value in many ways. They are small and light, and may be takenin a buggy or auto to any home or institution where the director alternating currents can be had. While they ar


Size: 1486px × 1681px
Photo credit: © Reading Room 2020 / Alamy / Afripics
License: Licensed
Model Released: No

Keywords: ., boo, bookcentury1900, bookdecade1910, booksubjecteye, bookyear1912