Electrical news and engineering . column with water gauge and three try cocks. The fronts are fitted with rolling tube header door. Heat-ing surface is 10,470 sq. ft. per boiler. The weight, approxi-mate, 150,000 lbs. each. Four Foster superheaters are installed, guaranteed toraise the temperature of 31,500 lbs. of steam per hour, at pres-sure 200 lbs. per sq. in., to 5,380 F. corresponding to super-heat at 150 deg. With boiler operating at 150 per cent, rat-ing, superheat is 160 deg. The stokers feed the boilers at a sufficient rate to forcethem to 235 per cent, of rating without difficulty.


Electrical news and engineering . column with water gauge and three try cocks. The fronts are fitted with rolling tube header door. Heat-ing surface is 10,470 sq. ft. per boiler. The weight, approxi-mate, 150,000 lbs. each. Four Foster superheaters are installed, guaranteed toraise the temperature of 31,500 lbs. of steam per hour, at pres-sure 200 lbs. per sq. in., to 5,380 F. corresponding to super-heat at 150 deg. With boiler operating at 150 per cent, rat-ing, superheat is 160 deg. The stokers feed the boilers at a sufficient rate to forcethem to 235 per cent, of rating without difficulty. Fig. 3 water purification. The water softening building is shownat the left of Fig. 1. The two reaction and settling tanks are: 24 ft. 6 in. indiameter, 19 ft. 4 in. high, dressed Washington fir, 2^4 , fitted with round steel hoops and malleable irondraw lugs. Tanks are provided with steel ladder outside andwooden ladder inside with platform at top of outside ladder,both tanks are covered. One inch pipe connection is pro-. during erection. shows a view of a portion of the boiler-room. The boilersare equipped with automatic soot blowers and the customaryinstruments to enable the engineers to operate the boiler intel-ligently. The flue gases are carried away by two radial brickchimneys. The chimneys were built by the Canadian Kellogg Com-pany. Dimensions: Height above foundations, 240 ft.; internal top diameter, 12ft.; height of base, 22 ft.; cross section of base, round inshape, 22 ft. 2 in. diameter; lining 40 ft. high from point 2ft. below flue opening; Baffle 20 ft. high and 8 in. thick; light-ning conductor 6 copper points. ^ in. diameter, 8 ft. long,with \l/2 in. solid platinum tips. Lower ends of points con-nected to proper cable encircling chimney from this cable:one 7/16 in. 7 strand No. 10 Stubbs gauge copper cable is car-ried to ground and connected to copper ground plates; one 1in. H. & M. patent gauge and connections; one 2 in. pyro-meter connection; steps of


Size: 1579px × 1582px
Photo credit: © The Reading Room / Alamy / Afripics
License: Licensed
Model Released: No

Keywords: ., bo, bookcentury1800, bookdecade1890, bookidelectricalnewsen28donm