. Florists' review [microform]. Floriculture. 96 The Florists'Review Sbptbmbbk 11, BUV UIKKCT FACTORY TO IT8£B PRICES MORE KROESCHELL BOILERS USED FOR GREENHOUSE HEATING THAN (ANYOTHEj [AKI KROESCHELL BROS. CO., 444 WrCtT ERIE STREET CfHCAQO, ILL. Mention The Review when yon write. to 63 degrees, are to be grown, the re-;, turns should be increased to ten 2-inob or twenty 1-inch pip^s. In choosing a boiler for heating the" two houses, it will be advisable to se- lect one with a rating of 1,200 square feet of radiation if a temperature of 50 to 55 degrees is desired, and 1,W0 square


. Florists' review [microform]. Floriculture. 96 The Florists'Review Sbptbmbbk 11, BUV UIKKCT FACTORY TO IT8£B PRICES MORE KROESCHELL BOILERS USED FOR GREENHOUSE HEATING THAN (ANYOTHEj [AKI KROESCHELL BROS. CO., 444 WrCtT ERIE STREET CfHCAQO, ILL. Mention The Review when yon write. to 63 degrees, are to be grown, the re-;, turns should be increased to ten 2-inob or twenty 1-inch pip^s. In choosing a boiler for heating the" two houses, it will be advisable to se- lect one with a rating of 1,200 square feet of radiation if a temperature of 50 to 55 degrees is desired, and 1,W0 square feet for 60 to 65 degrees. If there is a likelihood of an increase in the size of the range, it woul;j be well to provide heating capacity at this time to the extent of at least an ad- ditional 70-foot house. In case a still greater increase is to be made, it will be better to provide an additional boil- er when the addition is made. AN INDIANA LETTUCJE HOUSE. We are building a greenhouse, 21x50, and intend to grow lettuce and vegetable plants. We have a hot water boiler, with a rating of 1,250 square feet. It has six 2-inch outlets and the same number of openings for returns. Please state how many runs of 2-inch pipe, mains and returns, will be neces- sary to heat the house properly. What day and night temperatures should be maintained? A. P. R. I would suggest the use of two 2^- inch flow pipes and eight 2-inch returns. While it would be desirable to have 2V^-inch openings in the boiler for the flows and returm^ it will answer if the flows and returns are re- duced to 2-inch at the boiler. If piped as I have suggested, the flows should be on the plates and the returns should be either on the walls or under the side benches, if raised benches are used. Another way of piping the house would be to use three 2-inch flow pipes and nine or ten 2-inch returns. With this system of piping, which would give good results if there are raised benches in the middle of the house^ one of t


Size: 1581px × 1581px
Photo credit: © Library Book Collection / Alamy / Afripics
License: Licensed
Model Released: No

Keywords: ., bookcentury1900, bookdecad, booksubjectfloriculture, bookyear1912