. Electric railway review . e middle roof truss to be instantly illuminated fromthe oil-switch control battery in a case of a general powerinterruption which puts out the regular station Details. The method of leading the wires from the floor ductsto the back of the switchboard panels is rather unusual andis believed to have many advantages over the individualjunction boxes, bent tubing in wood sills, etc., that haveoften been employed. The switchboard panels stand on awood sill, which in turn rests on two channel-irons on edgewith ample space between them for handling and s
. Electric railway review . e middle roof truss to be instantly illuminated fromthe oil-switch control battery in a case of a general powerinterruption which puts out the regular station Details. The method of leading the wires from the floor ductsto the back of the switchboard panels is rather unusual andis believed to have many advantages over the individualjunction boxes, bent tubing in wood sills, etc., that haveoften been employed. The switchboard panels stand on awood sill, which in turn rests on two channel-irons on edgewith ample space between them for handling and spacingthe wires. The conduit projects just through the channelsand is capped off flush. Vertical bushings in the wood sillslead the wires from the ducts to the back of the panels. Theunder side of this opening between the channels can easilybe covered with steel plate so as to prevent injury to thewires from below. The oil-switch control battery is placed in a separateroom in the basement. This room is connected by means of. International Railway. Buffalo—Virginia Substation with Six 1,000-Kw. Rotaries. eating bulls eyes for the converter oil-switches on thedirect-current rotary panels as well as on the alternating-current panels. These switches on the direct-current panelsare only for use in emergency and are arranged so that theywill only open the oil-switches. The incoming power is measured on a single meter, re-gardless of the number of incoming cables in service. Thisis accomplished by paralleling the secondaries of the currenttransformers. Double-throw switches are provided for cut- a pipe laid in the floor, with the air-chamber under the trans-formers, and as there are windows in the battery room, theair can be changed at any rate desired. Next to the batteryroom is the store-room and station-attendants locker roomand opposite these is the toilet room. The whole basementis well ventilated by windows protected on the outside byboth screens and bars. The electrical appar
Size: 2273px × 1099px
Photo credit: © Reading Room 2020 / Alamy / Afripics
License: Licensed
Model Released: No
Keywords: ., bookcentury1900, bookdecade1900, booksubjectstreetr, bookyear1906