. calcomp :: H-84-0045B vistagraphic DR11W DR11B DR11C and DR11B parallel interface users manual Nov1984 . systemconfiguration; refer to the installation manual. In VIOOO and V3000 systems, note that cable connections vary depending onwhether your configuration includes an interconnect panel. Refer to theconnection diagram that pertains to your system on the following pages. For Vistagraphic 4500 systems, install the circuit board in slot A9 forrack-mount systems, slot A6 for tower units. SWITCH SETTINGS (PARALLEL INTERFACE BOARD) Each parallel interface card has three 8-section switches (
. calcomp :: H-84-0045B vistagraphic DR11W DR11B DR11C and DR11B parallel interface users manual Nov1984 . systemconfiguration; refer to the installation manual. In VIOOO and V3000 systems, note that cable connections vary depending onwhether your configuration includes an interconnect panel. Refer to theconnection diagram that pertains to your system on the following pages. For Vistagraphic 4500 systems, install the circuit board in slot A9 forrack-mount systems, slot A6 for tower units. SWITCH SETTINGS (PARALLEL INTERFACE BOARD) Each parallel interface card has three 8-section switches (see figure).Installing the card, check that the switches are properly set. Refer to thetables below. Settings for Switches SI and S2 PARALLEL SI S2 INTERFACE TYPE SETTINGS SETTINGS DRll-B All sections open All sections open DRU-W All sections closed All sections closed DRVU-B All sections closed All sections closed Settings for Switch S3 SWITCH SECTION VIOOO, 3000 V4000, V4500 1 Open Closed 2 Open Closed 3 Closed Closed 4 Open Open 5 Closed Closed 6 Open Open 7 Closed Open 8 Closed Open 11 Change 1 (. Switch Locations2o3 SWITCH SETTING (SYSTEM PROCESSOR) The system processor board contains switches that are set to correspond with theparallel interface boardo Vistagraphic 1000 and 3000 systems use only 18-bitaddressing! the switches are factory set and do not need to be altered« Vistagraphic 4000 and 4500 system processor boards use a switch(es) thatcorresponds with various character fraiding and 18- and 24-bit addressing. Forinformation regarding these settings, refer to the maintenance manual for yourparticular systems V4000 - H-81-0352B (Section 2)¥4500 ^ H-83-0612 (Section 2) ( 12 Change 1 SYSTEM I/OPANEL 5810015CIRCUIT CARD 6003249G2 J3 ^.600324903 V4500 r PARALLEL INTERFACE A PARALLELINTERFACE B C3 <3 DR11-W TWO 6003250G1 25 CABLESOR TWO 6003250G2 50* CABLES HOST H-84-0045-025 Connection Diagram DRU-W (V4500) 5810015G1 J2 CIRCUIT CARD J3 ^ TWO 58n454G1 6 CABLESOR TWO
Size: 2093px × 1194px
Photo credit: © Reading Room 2020 / Alamy / Afripics
License: Licensed
Model Released: No
Keywords: ., bookcentury1900, bookdecade1910, bookidbitsaverscal, bookyear1919